7.5.4.10 Pset_BoilerTypeSteam

PSET_TYPEDRIVENOVERRIDE / IfcBoiler / STEAM

Natural language names
Boiler Type Steam
Properties

buildingSMART Data Dictionary

PSD-XML

NameTypeDescription
MaximumOutletPressure P_SINGLEVALUE / IfcLabel
Maximum Outlet PressureMaximum steam outlet pressure.
PressionSortieAdmissiblePression vapeur en sortie maximale
鏈澶у嚭鍙e湩鍔鏈澶у嚭鍙h捀姘楀湩鍔
NominalEfficiency P_TABLEVALUE / IfcThermodynamicTemperatureMeasure / IfcNormalisedRatioMeasure
Nominal EfficiencyThe nominal efficiency of the boiler as defined by the manufacturer. For steam boilers, a function of inlet temperature versus steam pressure. Note: as two variables are used, DefiningValues and DefinedValues are null, and values are stored in IfcTable in the following order: InletTemperature(IfcThermodynamicTemperatureMeasure) and OutletTemperature(IfcThermodynamicTemperatureMeasure) in DefiningValues, and NominalEfficiency(IfcNormalisedRatioMeasure) in DefinedValues. For example, DefininfValues(InletTemp, OutletTemp), DefinedValues(null, NominalEfficiency). The IfcTable is related to IfcPropertyTableValue using IfcMetric and IfcPropertyConstraintRelationship.
Efficacit茅NominaleEfficacit茅 nominale de la chaudi猫re tel que d茅finie par le constructeur. Pour les chaudi猫res 脿 vapeur, une fonction de la temp茅rature en entr茅e par rapport 脿 la pression de vapeur. Remarque: Comme deux variables sont utilis茅es ValeurDefinir et ValeursDefinies sont nulles, et les valeurs sont enregistr茅es dans IfcTable dans l'ordre suivant: - Temp茅ratureEntr茅e (IfcThermodynamicTemperatureMeasure) et Temp茅ratureSortie (IfcThermodynamicTemperatureMeasure) dans ValeursDefinir , et Efficacit茅Nominale (IfcNormalisedRatioMeasure) dansValeursDefinies. Par exemple, ValeursDefinir (Temp茅ratureEntr茅e, Temp茅ratureSortie), ValeursDefinies (nul, RendementNominal). IfcTable est li茅 脿 IfcPropertyTableValue qui utilise IfcMetric et IfcPropertyConstraintRelationship.
HeatOutput P_TABLEVALUE / IfcThermodynamicTemperatureMeasure / IfcEnergyMeasure
Heat OutputTotal nominal heat output as listed by the Boiler manufacturer. For steam boilers, it is a function of inlet temperature versus steam pressure. Note: as two variables are used, DefiningValues and DefinedValues are null, and values are stored in IfcTable in the following order: InletTemperature(IfcThermodynamicTemperatureMeasure) and OutletTemperature(IfcThermodynamicTemperatureMeasure) in DefiningValues, and HeatOutput(IfcEnergyMeasure) in DefinedValues. For example, DefiningValues(InletTemp, OutletTemp), DefinedValues(null, HeatOutput). The IfcTable is related to IfcPropertyTableValue using IfcMetric and IfcPropertyConstraintRelationship.
RendementChaleurRendement total nominal tel que d茅fini par le constructeur de chaudi猫re. Pour les chaudi猫res 脿 vapeur, une fonction de la temp茅rature en entr茅e par rapport 脿 la pression de vapeur. Remarque: Comme deux variables sont utilis茅es ValeurDefinir et ValeursDefinies sont nulles, et les valeurs sont enregistr茅es dans IfcTable dans l'ordre suivant: - Temp茅ratureEntr茅e (IfcThermodynamicTemperatureMeasure) et Temp茅ratureSortie (IfcThermodynamicTemperatureMeasure) dans ValeursDefinir , et Rendement de chaleur (IfcEnergyMeasure) dansValeursDefinies. Par exemple, ValeursDefinir (Temp茅ratureEntr茅e, Temp茅ratureSortie), ValeursDefinies (nul, RendementChaleur). IfcPropertyTable est li茅 脿 IfcMetric qui utilise IfcMetric et IfcPropertyConstraintRelationship.