7.4.4.20 Pset_CableSegmentTypeCableSegment

PSET_TYPEDRIVENOVERRIDE / IfcCableSegment / CABLESEGMENT

Natural language names
Cable Segment Type Cable Segment
Properties

buildingSMART Data Dictionary

PSD-XML

NameTypeDescription
Standard P_SINGLEVALUE / IfcLabel
StandardThe designation of the standard applicable for the definition of the Cable/Bus used.
妯欐簴浣跨敤銇曘倢銈嬨偙銉笺儢銉乥usbar銇畾缇┿伄銇熴倎銇娇鐢ㄣ仌銈屻倠妯欐簴浠曟銆
NumberOfCores P_SINGLEVALUE / IfcInteger
Number Of CoresThe number of cores in Cable/Bus.
鑺暟銈便兗銉栥儷銈勬瘝绶氥伄鑺暟銈掔ず銇欍
OverallDiameter P_SINGLEVALUE / IfcPositiveLengthMeasure
Overall DiameterThe overall diameter of a Cable/Bus.
鐩村緞銈便兗銉栥儷銈勬瘝绶氥伄澶栧舰瀵告硶锛堢洿寰勶級銈掔ず銇欍
RatedVoltage P_BOUNDEDVALUE / IfcElectricVoltageMeasure *
Rated VoltageThe voltage that a device is designed to handle.
RatedTemperature P_BOUNDEDVALUE / IfcThermodynamicTemperatureMeasure
Rated TemperatureThe range of allowed temerature that a device is certified to handle. The upper bound of this value is the maximum.
瀹氭牸娓╁害浣跨敤銇с亶銈嬨亾銇ㄣ亴瑷卞彲銇曘倢銇︺亜銈嬭ū瀹规俯搴︺
ScreenDiameter P_SINGLEVALUE / IfcPositiveLengthMeasure
Screen DiameterThe diameter of the screen around a cable or bus segment (if present).
銈广偗銉兗銉冲緞閬伕銇勫堡銇緞銆佸帤銇曘
HasProtectiveEarth P_SINGLEVALUE / IfcBoolean *
Has Protective EarthIndicates whether the electrical device has a protective earth connection (=TRUE) or not (= FALSE).
MaximumOperatingTemperature P_SINGLEVALUE / IfcThermodynamicTemperatureMeasure
Maximum Operating TemperatureThe maximum temperature at which a cable or bus is certified to operate.
瑷卞鏈楂樻俯搴銈便兗銉栥儷銈勬瘝绶氥伄鏈澶у嫊浣滄俯搴︺倰绀恒仚銆
MaximumShortCircuitTemperature P_SINGLEVALUE / IfcThermodynamicTemperatureMeasure
Maximum Short Circuit TemperatureThe maximum short circuit temperature at which a cable or bus is certified to operate.
鐭怠瑷卞鏈楂樻俯搴銈便兗銉栥儷銈勬瘝绶氥伄鏈澶х煭绲℃俯搴︺倰绀恒仚銆
SpecialConstruction P_SINGLEVALUE / IfcLabel
Special ConstructionSpecial construction capabilities like self-supporting, flat devidable cable or bus flat non devidable cable or bus supporting elements inside (steal, textile, concentric conductor). Note that materials used should be agreed between exchange participants before use.
鐗瑰垾銇柦宸ユ柟娉鐗规畩銇閫犮倰鍌欍亪銇熸ц兘锛嶃仧銇ㄣ亪銇般佸钩鍨嬨儠銉偔銈枫儢銉偙銉笺儢銉亗銈嬨亜銇‖銇勫钩鍨嬫瘝绶氥偙銉笺儢銉併亗銈嬨亜銇瘝绶氥仹鍐呴儴銇墑瑁姐佺箠缍佸悓蹇冨皫浣撱仹妲嬫垚銇曘倢銇︺亜銈嬨偟銉濄兗銉堛倰鎸併仯銇︺亜銈嬨 娉ㄨ锛変娇鐢ㄣ仚銈嬫潗鏂欍伅銆佷娇鐢ㄥ墠銇氦娴佸弬鍔犺呴枔銇у悎鎰忋仚銈嬨亾銇ㄣ
Weight P_SINGLEVALUE / IfcMassMeasure
WeightWeight of cable kg/km.
閲嶉噺銈便兗銉栥儷銇噸閲忋
SelfExtinguishing60332_1 P_SINGLEVALUE / IfcBoolean
Self Extinguishing60332_1Self Extinguishing cable/core according to IEC 60332.1.
鑷繁娑堢伀銈便兗銉栥儷IEC 60332.1.銇瀹氥仌銈屻仸銇勩倠鑷繁娑堢伀銈便兗銉栥儷銆
SelfExtinguishing60332_3 P_SINGLEVALUE / IfcBoolean
Self Extinguishing60332_3Self Extinguishing cable/core according to IEC 60332.3.
鑷繁娑堢伀銈便兗銉栥儷IEC 60332.3.銇瀹氥仌銈屻仸銇勩倠鑷繁娑堢伀銈便兗銉栥儷銆
HalogenProof P_SINGLEVALUE / IfcBoolean
Halogen ProofProduces small amount of smoke and irritating Deaerator/Gas.
銈ㄣ偝銈便兗銉栥儷鐓欍倓鍒烘縺鑷伄銇傘倠銈偣銇櫤鐢熴亴灏戙仾銇勩偙銉笺儢銉
FunctionReliable P_SINGLEVALUE / IfcBoolean
Function ReliableCable/bus maintain given properties/functions over a given (tested) time and conditions. According to IEC standard.
淇¢牸鎬с伄銇傘倠姗熻兘銈便兗銉栥儷銈勬瘝绶氥亴涓庛亪銈夈倢銇熸檪闁撱仺鏉′欢銇腑銇ц瀹氥仌銈屻倠姗熻兘銆佹ц唱銈掔董鎸併仚銈嬨亾銇ㄣ傘亾銈屻伅IEC鍩烘簴銇倛銈嬨