Name | Type | Description |
ChamberLengthOrRadius |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Chamber Length Or Radius | Length or, in the event of the shape being circular in plan, the radius of the chamber. |
| 銉併儯銉炽儛銉硷紙銉愩偆銉栥偣銉氥兗銈癸紵锛夈伄闀枫仌銇傘倠銇勩伅鍗婂緞 | 銉併儯銉炽儛銉笺伄闀枫仌銇傘倠銇勩伅鍐嗗舰銉併儯銉炽儛銉笺伄鍗婂緞銆 |
|
ChamberWidth |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Chamber Width | Width, in the event of the shape being non circular in plan. |
| 銉併儯銉炽儛銉硷紙銉愩偆銉栥偣銉氥兗銈癸紵锛夈伄骞 | 闈炲唵褰€儊銉c兂銉愩兗銇箙銆 |
|
InvertLevel |
P_SINGLEVALUE
/
IfcLengthMeasure
|
| Invert Level | Level of the lowest part of the cross section as measured from ground level. |
| 鏈澶ф繁銇 | 鏂潰銇渶銈備綆銇勯儴鍒嗐伄娣便仌锛堝湴闈€亱銈夛級銆 |
|
SoffitLevel |
P_SINGLEVALUE
/
IfcLengthMeasure
|
| Soffit Level | Level of the highest internal part of the cross section as measured from ground level. |
| 鏈灏忔繁銇 | 鏂潰銇渶銈傞珮銇勯儴鍒嗐伄娣便仌锛堝湴闈€亱銈夛級銆 |
|
WallMaterial |
P_REFERENCEVALUE
/
IfcMaterialDefinition
|
| Wall Material | The material from which the wall of the chamber is constructed.
NOTE: It is assumed that chamber walls will be constructed of a single material. |
| 澹併伄鏉愯唱 | 銉銈儓銈广儦銉笺偣澹併伄鏉愯唱銆
娉細銉銈儓銈广儦銉笺偣銇銇崢灞ゃ仺浠畾銇欍倠 |
|
WallThickness |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Wall Thickness | The thickness of the chamber wall construction
NOTE: It is assumed that chamber walls will be constructed at a single thickness. |
| 澹佸帤銇 | 銉銈儓銈广儦銉笺偣澹併伄鍘氥仌銆
娉細銉銈儓銈广儦銉笺偣銇銇崢灞ゃ仺浠畾銇欍倠 |
|
BaseMaterial |
P_REFERENCEVALUE
/
IfcMaterialDefinition
|
| Base Material | The material from which the base of the chamber is constructed.
NOTE: It is assumed that chamber base will be constructed of a single material. |
| 搴娿伄鏉愯唱 | 銉銈儓銈广儦銉笺偣搴婇潰銇潗璩
娉細銉銈儓銈广儦銉笺偣銇簥銇崢灞ゃ仺浠畾銇欍倠 |
|
BaseThickness |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Base Thickness | The thickness of the chamber base construction
NOTE: It is assumed that chamber base will be constructed at a single thickness. |
| 搴娿伄鍘氥仌 | 銉銈儓銈广儦銉笺偣搴婇潰銇帤銇曘
娉細銉銈儓銈广儦銉笺偣銇簥銇崢灞ゃ仺浠畾銇欍倠 |
|
WithBackdrop |
P_SINGLEVALUE
/
IfcBoolean
|
| With Backdrop | Indicates whether the chamber has a backdrop or tumbling bay (TRUE) or not (FALSE). |
| 銉愩儍銈儔銉儍銉椾粯銇 | 銉銈儓銈广儦銉笺偣銇儛銉冦偗銉夈儹銉冦儣鎴栥亜銇牥浠樸亼銇嬨仼銇嗐亱锛圱RUE鎴栥亜銇疐ALSE锛夈 |
|
AccessCoverMaterial |
P_REFERENCEVALUE
/
IfcMaterialDefinition
|
| Access Cover Material | The material from which the access cover to the chamber is constructed.
NOTE: It is assumed that chamber walls will be constructed of a single material. |
| 銈€偗銈汇偣锛堢偣妞滐級銈儛銉笺伄鏉愯唱 | 銈€偗銈汇偣锛堢偣妞滐級銈儛銉笺伄鏉愯唱銆
娉細銉愩偆銉栥偣銉氥兗銈广伄澹併伅鍗樺堡銇ㄤ划瀹氥仚銈 |
|
AccessLengthOrRadius |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Access Length Or Radius | The length of the chamber access cover or, where the plan shape of the cover is circular, the radius. |
| 銈€偗銈汇偣锛堢偣妞滐級銈儛銉笺伄闀枫仌鎴栥亜銇崐寰 | 銈€偗銈汇偣锛堢偣妞滐級銈儛銉笺伄闀枫仌銆佹垨銇勩伅鍐嗗舰銈儛銉笺伄鍗婂緞銆 |
|
AccessWidth |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Access Width | The width of the chamber access cover where the plan shape of the cover is not circular. |
| 銈€偗銈汇偣锛堢偣妞滐級銈儛銉笺伄骞 | 銈€偗銈汇偣锛堢偣妞滐級銈儛銉笺伄骞呫 |
|
AccessCoverLoadRating |
P_SINGLEVALUE
/
IfcText
|
| Access Cover Load Rating | The load rating of the access cover (which may be a value or an alphanumerically defined class rating). |
| 銈€偗銈汇偣锛堢偣妞滐級銈儛銉笺伄鑰愯嵎閲 | 銈€偗銈汇偣锛堢偣妞滐級銈儛銉笺伄鑰愯嵎閲嶏紙鏁板瓧鎴栥亜銇偄銉儠銈°儥銉冦儓銇у畾缇┿仚銈嬶級銆 |
|