Name | Type | Description |
SprinklerType |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_SprinklerType |
| Sprinkler Type | Identifies the predefined types of sprinkler from which the type required may be set. |
| 銈广儣銉兂銈儵銉笺偪銈ゃ儣 | 銇傘倝銇嬨仒銈佸畾缇╂笀銇裤伄銈广儣銉兂銈儵銉笺伄鍨嬨亱銈夊繀瑕併仾鍨嬨倰瑷畾銇欍倠璀樺垾銆 |
|
Activation |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_SprinklerActivation |
| Activation | Identifies the predefined methods of sprinkler activation from which that required may be set. |
| 浣滃嫊 | 銇傘倝銇嬨仒銈佸畾缇╂笀銇裤伄銈广儣銉兂銈儵銉笺伄浣滃嫊鏂瑰紡銇嬨倝蹇呰銇柟寮忋倰瑷畾銇欍倠璀樺垾銆 |
|
Response |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_SprinklerResponse |
| Response | Identifies the predefined methods of sprinkler response from which that required may be set. |
| 蹇滅瓟 | 銇傘倝銇嬨仒銈佸畾缇╂笀銇裤伄銈广儣銉兂銈儵銉笺伄蹇滅瓟鏂瑰紡銇嬨倝蹇呰銇柟寮忋倰瑷畾銇欍倠璀樺垾銆 |
|
ActivationTemperature |
P_SINGLEVALUE
/
IfcThermodynamicTemperatureMeasure
|
| Activation Temperature | The temperature at which the object is designed to activate. |
| 浣滃嫊娓╁害 | 瑷▓浣滃嫊娓╁害銆 |
|
CoverageArea |
P_SINGLEVALUE
/
IfcAreaMeasure
|
| Coverage Area | The area that the sprinkler is designed to protect. |
| 銈儛銉奸潰绌 | 銈广儣銉兂銈儵銉笺伄瑷▓淇濊鍖虹敾闈㈢⿳銆 |
|
HasDeflector |
P_SINGLEVALUE
/
IfcBoolean
|
| Has Deflector | Indication of whether the sprinkler has a deflector (baffle) fitted to diffuse the discharge on activation (= TRUE) or not (= FALSE). |
| 銉囥偅銉曘儸銈偪銉笺伄鏈夌劇 | 銈广儣銉兂銈儵銉间綔鍕曟檪銆佹斁姘淬倰鎷℃暎銇曘仜銈嬪亸鍚戝櫒锛堛儛銉冦儠銉級鍙栥倞浠樸亼銇︺亜銈嬨亱銇┿亞銇嬨伄琛ㄧず锛= TRUE锛夈仢銇嗐仹銇亜銇嬶紙= FALSE锛夈倰杩斻仐銇俱仚銆 |
|
BulbLiquidColor |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_SprinklerBulbLiquidColor |
| Bulb Liquid Color | The color of the liquid in the bulb for a bulb activated sprinkler. Note that the liquid color varies according to the activation temperature requirement of the sprinkler head. Note also that this property does not need to be asserted for quick response activated sprinklers. |
| 銉愩儷銉栨恫浣撹壊 | 銉愩儷銉栦綔鍕曘偣銉椼儶銉炽偗銉┿兗銇儛銉儢娑蹭綋鑹层伄瑷畾銆傛恫浣撹壊銇併偣銉椼儶銉炽偗銉┿兗銉樸儍銉夈伄浣滃嫊娓╁害銇繙銇樸仸澶夊寲銇欍倠銆傘伨銇熴併亾銇睘鎬с伅銆侀珮閫熷繙绛斻偣銉椼儶銉炽偗銉┿兗銇ō瀹氥仚銈嬪繀瑕併伅銇亜銆 |
|
DischargeFlowRate |
P_SINGLEVALUE
/
IfcVolumetricFlowRateMeasure
|
| Discharge Flow Rate | The volumetric rate of fluid discharge. |
| 鍚愬嚭娴侀噺 | 鍚愬嚭娴佷綋銇綋绌嶆祦閲忋 |
|
ResidualFlowingPressure |
P_SINGLEVALUE
/
IfcPressureMeasure
|
| Residual Flowing Pressure | The residual flowing pressure in the pipeline at which the discharge flow rate is determined. |
| 娈嬬暀娴佸嫊鍦у姏 | 鍚愬嚭娴侀噺銇岀⒑淇濄仌銈屻倠銆併儜銈ゃ儣銉┿偆銉炽伄娴併倢鏅傛畫鐣欏湩鍔涖 |
|
DischargeCoefficient |
P_SINGLEVALUE
/
IfcReal
|
| Discharge Coefficient | The coefficient of flow at the sprinkler. |
| 娴侀噺淇傛暟 | 銈广儣銉兂銈儵銉笺伄娴併倢銇總鏁般 |
|
MaximumWorkingPressure |
P_SINGLEVALUE
/
IfcPressureMeasure
|
| Maximum Working Pressure | Maximum pressure that the object is manufactured to withstand. |
| 鏈澶т綔鍕曞湩鍔 | 鏈澶у湩鍔涖佽=閫犺愬湩銆 |
|
ConnectionSize |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Connection Size | Size of the inlet connection to the sprinkler. |