6.2.4.26 Pset_SpaceThermalLoadPHistory

PSET_PERFORMANCEDRIVEN / IfcSpace

Natural language names
Space Thermal Load PHistory
Properties

buildingSMART Data Dictionary

PSD-XML

NameTypeDescription
People P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
PeopleHeat gains and losses from people.
浜哄摗浜哄摗銇嬨倝銇啽鍙栧緱銆
Lighting P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
LightingLighting loads.
鐓ф槑鐓ф槑璨犺嵎銆
EquipmentSensible P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Equipment SensibleHeat gains and losses from equipment.
浜嬪嫏姗熷櫒銇鐔浜嬪嫏姗熷櫒銇嬨倝銇啽鍙栧緱銇ㄧ啽銉偣銆
VentilationIndoorAir P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Ventilation Indoor AirVentilation loads from indoor air.
瀹ゅ唴銇彌姘楅噺瀹ゅ唴銇彌姘椼伀銈堛倠鐔辫矤鑽枫
VentilationOutdoorAir P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Ventilation Outdoor AirVentilation loads from outdoor air.
澶栨皸閲澶栨皸銇倛銈嬬啽璨犺嵎銆
RecirculatedAir P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Recirculated AirLoads from recirculated air.
寰挵绌烘皸寰挵绌烘皸銇倛銈嬬啽璨犺嵎銆
ExhaustAir P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Exhaust AirLoads from exhaust air.
鎺掓皸鎺掓皸銇倛銈嬬啽璨犺嵎銆
AirExchangeRate P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Air Exchange RateLoads from the air exchange rate.
鎻涙皸鍥炴暟鎻涙皸銇倛銈嬬啽璨犺嵎銆
DryBulbTemperature P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Dry Bulb TemperatureLoads from the dry bulb temperature.
涔剧悆娓╁害涔剧悆娓╁害銇倛銈嬬啽璨犺嵎銆
RelativeHumidity P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Relative HumidityLoads from the relative humidity.
鐩稿婀垮害鐩稿婀垮害銇倛銈嬬啽璨犺嵎銆
InfiltrationSensible P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Infiltration SensibleHeat gains and losses from infiltration.
銇欍亶闁撻ⅷ銇鐔銇欍亶闁撻ⅷ銇嬨倝銇啽璨犺嵎銇ㄧ啽銉偣銆
TotalSensibleLoad P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Total Sensible LoadTotal energy added or removed from air that affects its temperature. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
椤曠啽璨犺嵎銇悎瑷绌烘皸娓╁害銈掍笂鏄囥兓涓嬮檷銇曘仜銈嬪彇寰椼兓鎼嶅け銇啽閲忋伄鍚堣▓銆傘偧銉倛銈婂皬銇曘亜锛堬紞锛夊牬鍚堛佸鍐呫亴鐔辨悕澶便仺銇倠銆傘偧銉倛銈婂ぇ銇嶃亜锛堬紜锛夊牬鍚堛佸鍐呫亴鐔卞彇寰椼仺銇倠銆
TotalLatentLoad P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Total Latent LoadTotal energy added or removed from air that affects its humidity or concentration of water vapor. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
娼滅啽璨犺嵎銇悎瑷绌烘皸婀垮害锛堟按钂告皸閲忥級銈掍笂鏄囥兓涓嬮檷銇曘仜銈嬪彇寰椼兓鎼嶅け銇啽閲忋伄鍚堣▓銆傘偧銉倛銈婂皬銇曘亜锛堬紞锛夊牬鍚堛佸鍐呫伄姘磋捀姘椼亴娓涘皯銇ㄣ仾銈嬨傘偧銉倛銈婂ぇ銇嶃亜锛堬紜锛夊牬鍚堛佸鍐呫伄姘磋捀姘椼亴澧楀ぇ銇ㄣ仾銈嬨
TotalRadiantLoad P_REFERENCEVALUE / IfcTimeSeries / IfcPowerMeasure
Total Radiant LoadTotal electromagnetic energy added or removed by emission or absorption. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space.
鏀惧皠鐔辫矤鑽枫伄鍚堣▓鏀惧皠銈勫惛鍙庛伀銈堛倠鏀惧皠銈ㄣ儘銉偖銉笺伄澧楀姞銆佹垨銇勩伅娓涘皯銇悎瑷堛傘偧銉倛銈婂皬銇曘亜锛堬紞锛夊牬鍚堛佹斁灏勩偍銉嶃儷銈兗銇屾笡灏戙仺銇倠銆傘偧銉倛銈婂ぇ銇嶃亜锛堬紜锛夊牬鍚堛佹斁灏勩偍銉嶃儷銈兗銇屽澶с仺銇倠銆

Link to this page  Link to this page