Name | Type | Description |
NominalBodyLength |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Nominal Body Length | Nominal or quoted length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the chamber of the trap. |
| 鍛肩О韬綋闀 | 闃茶嚟寮併伄鍖虹敾銇崐寰勩亱灞鎵搴ф绯汇伄锛歌桓銇部銇c仸娓畾銇曘倢銇熷懠绉般倐銇椼亸銇⿳绠椼仌銈屻仧闀枫仌銆 |
|
NominalBodyWidth |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Nominal Body Width | Nominal or quoted length measured along the y-axis in the local coordinate system of the chamber of the trap. |
| 鍛肩О韬綋骞 | 闃茶嚟寮併伄鍖虹敾銇崐寰勩亱灞鎵搴ф绯汇伄锛硅桓銇部銇c仸娓畾銇曘倢銇熷懠绉般倐銇椼亸銇⿳绠椼仌銈屻仧闀枫仌銆 |
|
NominalBodyDepth |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Nominal Body Depth | Nominal or quoted length measured along the z-axis in the local coordinate system of the chamber of the trap. |
| 鍛肩О韬綋娣便仌 | 闃茶嚟寮併伄鍖虹敾銇崐寰勩亱灞鎵搴ф绯汇伄Z杌搞伀娌裤仯銇︽脯瀹氥仌銈屻仧鍛肩О銈傘仐銇忋伅绌嶇畻銇曘倢銇熼暦銇曘 |
|
IsForSullageWater |
P_SINGLEVALUE
/
IfcBoolean
|
| Is For Sullage Water | Indicates if the purpose of the floor trap is to receive sullage water, or if that is amongst its purposes (= TRUE), or not (= FALSE). Note that if TRUE, it is expected that an upstand or kerb will be placed around the floor trap to prevent the ingress of surface water runoff; the provision of the upstand or kerb is not dealt with in this property set. |
| 姹氭按鐢 | 搴婃帓姘撮槻鑷紒銇洰鐨勩亴銆佹睔姘淬倰鍙椼亼銈嬨亾銇ㄣ伄鍙紙=true)鍚(=false)銈掔ず銇欍
娉ㄦ剰锛歍RUE銇牬鍚堛佹按銇祦鍏ャ倰闃层亹銇熴倎銇簥闃茶嚟寮併伄鍛ㄣ倞銇洿绔嬪銇嬬竵鐭炽亴閰嶇疆銇曘倢銆併亾銇儣銉儜銉嗐偅銈汇儍銉堛伀銇娿亜銇︺伅鐩寸珛澹併倓绺佺煶銇彁渚涖伅鍑︾悊銇曘倢銇亜銆 |
|
SpilloverLevel |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Spillover Level | The level at which water spills out of the terminal. |
| 姘翠綅 | 缍欐墜銇嬨倝銇按浣嶃 |
|
TrapType |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_TrapType |
| Trap Type | Identifies the predefined types of waste trap used in combination with the floor trap from which the type required may be set. |
| 闃茶嚟寮併伄绋 | 銈汇儍銉堛仌銈屻倠浜堝畾銇簥銇槻鑷紒銇ㄧ祫銇垮悎銈忋仜銇︿娇銈忋倢銈嬪粌妫勭墿銇槻鑷紒銇亗銈夈亱銇樸倎瀹氱京銇曘倢銇熴偪銈ゃ儣銇瓨鍒ユ儏鍫便 |
|
HasStrainer |
P_SINGLEVALUE
/
IfcBoolean
|
| Has Strainer | Indicates whether the gully trap has a strainer (= TRUE) or not (= FALSE). |
| 銈嶉亷瑁呯疆 | 婧濄伄闃茶嚟寮併亴銈嶉亷瑁呯疆銈掑倷銇堛仸銇勩倠銇嬨仼銇嗐亱鎸囩ず銇欍倠銆 |
|
OutletConnectionSize |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Outlet Connection Size | Size of the outlet connection from the object. |
| 鎺ョ稓鍙e彛寰 | 瑕佺礌銇嬨倝銇帴缍氬彛鍙e緞銆 |
|
InletPatternType |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_InletPatternType |
| Inlet Pattern Type | Identifies the pattern of inlet connections to a trap.
A trap may have 0,1,2,3 or 4 inlet connections and the pattern of their arrangement may vary. The enumeration makes the convention that an outlet is either vertical or is placed at the bottom (south side) of the trap (when viewed in plan). Position 1 is to the left (west), position 2 is to the top (north), position 3 is to the right (east) and position 4 is to the bottom (south). |
| 鍚告皸鍙gó椤 | 闃茶嚟寮併伄鍚告皸鍙f帴缍氬彛銇瓨鍒ユ儏鍫便
涓銇ゃ伄闃茶嚟寮併伀0.1.2.3.4.銇惛姘楀彛鎺ョ稓鍙c仺銉戙偪銉笺兂銇屻亗銈嬨仺銇嶃伅澶夊寲銇欍倠鍙兘鎬с亴銇傘倞銇俱仚銆傜緟鍒椼仌銈屻倠銇ㄣ亶銆佹帴缍氬彛銇屽瀭鐩淬仹銇傘倠妲樺瓙銇嬨侀槻鑷紒銇簳锛堝崡锛夈伀銇娿亱銈屻伨銇欍備綅缃1銇乏(瑗)銇佷綅缃2銇笂鏂(鍖)銇佷綅缃3銇彸(鏉)銇佷綅缃4銇笅鏂(鍗楋級銇仾銈嬨 |
|
InletConnectionSize |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Inlet Connection Size | Size of the inlet connection(s), where used, of the inlet connections.
Note that all inlet connections are assumed to be the same size. |
| 鍚告皸鍙c偟銈ゃ偤 | 鍚告皸鍙f帴缍氬彛銇偟銈ゃ偤
娉ㄦ剰锛氬悓銈点偆銈恒伄鍚告皸鍙f帴缍氬彛銇屻仾銇勩倐銇仺銇欍倠銆 |
|
CoverLength |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Cover Length | The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the trap. |
| 銈儛銉奸暦銇 | 灞鎵搴ф绯汇伄X杌搞伀娌裤亞銇嬨佸崐寰勶紙鍐嗙姸銇舰銇牬鍚堬級銇ф脯瀹氥仌銈屻仧闃茶嚟寮併偒銉愩兗銇暦銇曘 |
|
CoverWidth |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Cover Width | The length measured along the y-axis in the local coordinate system of the cover of the trap. |
| 銈儛銉煎箙 | 灞鎵搴ф绯汇伄Y杌搞仹娓畾銇曘倢銇熼槻鑷紒銈儛銉笺伄闀枫仌銆 |
|
CoverMaterial |
P_REFERENCEVALUE
/
IfcMaterialDefinition
|
| Cover Material | Material from which the cover or grating is constructed. |
| 銈儛銉兼潗璩 | 銈儛銉笺亱鏍煎瓙銇潗璩 |
|