Name | Type | Description |
NominalSumpLength |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Nominal Sump Length | Nominal or quoted length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the sump. |
| 姹氭按妲介暦銇 | 灞鎵搴ф绯汇伄X杌搞伀娌裤亞銇嬪崐寰勶紙鍐嗙姸銇舰銇牬鍚堬級銇ф脯瀹氥仌銈屻仧銆佹睔姘存Ы銇暦銇曘 |
|
NominalSumpWidth |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Nominal Sump Width | Nominal or quoted length measured along the y-axis in the local coordinate system of the sump. |
| 姹氭按妲藉箙 | 灞鎵搴ф绯汇伄Y杌搞伀娌裤亞褰€仹娓畾銇曘倢姹氭按妲姐伄闀枫仌銆 |
|
NominalSumpDepth |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Nominal Sump Depth | Nominal or quoted length measured along the z-axis in the local coordinate system of the sump. |
| 姹氭按妲芥繁銇 | 灞鎵搴ф绯汇伄Z杌搞伀娌裤亞褰€仹娓畾銇曘倢姹氭按妲姐伄闀枫仌銆 |
|
GullyType |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_GullyType |
| Gully Type | Identifies the predefined types of gully from which the type required may be set. |
| 婧濈ó椤 | 蹇呰銇ㄣ仌銈屻倠銈裤偆銉椼亴銈汇儍銉堛仌銈屻倠婧濄伄瀹氱京銇曘倢銇熴偪銈ゃ儣銈掔⒑瑾嶃仐銇︺亸銇犮仌銇勩 |
|
TrapType |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_TrapType |
| Trap Type | Identifies the predefined types of trap from which the type required may be set. |
| 闃茶嚟寮佺ó椤 | 蹇呰銇ㄣ仌銈屻倠銈裤偆銉椼亴銈汇儍銉堛仌銈屻倠闃茶嚟寮併伄瀹氱京銇曘倢銇熴偪銈ゃ儣銈掔⒑瑾嶃仐銇︺亸銇犮仌銇勩 |
|
OutletConnectionSize |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Outlet Connection Size | Size of the outlet connection from the object. |
| 鎺掓皸鍙f帴缍氬彛 | 瑕佺礌銇嬨倝銇帓姘楀彛鎺ョ稓鍙c伄銈点偆銈恒 |
|
BackInletPatternType |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_BackInletPatternType |
| Back Inlet Pattern Type | Identifies the pattern of inlet connections to a gully trap.
A gulley trap may have 0,1,2,3 or 4 inlet connections and the pattern of their arrangement may vary. The enumeration makes the convention that an outlet is either vertical or is placed at the bottom (south side) of the gully trap (when viewed in plan). Position 1 is to the left (west), position 2 is to the top (north), position 3 is to the right (east) and position 4 is to the bottom (south).
2
|
----------------
! |
1-| |-3
! |
----------------
|
4 |
| 鑳岄儴鎺ョ稓鍙gó椤 | 婧濋槻鑷紒銇惛姘楀彛銉戙偪銉笺兂銈掔⒑瑾嶃仐銇︺亸銇犮仌銇勩
涓銇ゃ伄婧濋槻鑷紒銇0.1.2.3.4.銇惛姘楀彛鎺ョ稓鍙c仺銉戙偪銉笺兂銇屻亗銈嬨仺銇嶃伅澶夊寲銇欍倠鍙兘鎬с亴銇傘倞銇俱仚銆傝〃瑷樸仌銈屻倠銇ㄣ亶銇佹帴缍氬彛銇屽瀭鐩淬仹銇傘倠妲樺瓙銇嬨侀槻鑷紒銇簳锛堝崡锛夈伀銇娿亱銈屻伨銇欍備綅缃1銇乏(瑗)銇佷綅缃2銇笂鏂(鍖)銇佷綅缃3銇彸(鏉)銇佷綅缃4銇笅鏂(鍗楋級銇仾銈娿伨銇欍 |
|
InletConnectionSize |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Inlet Connection Size | Size of the inlet connection(s), where used, of the inlet connections.
Note that all inlet connections are assumed to be the same size. |
| 鍚告皸鍙f帴缍氬彛銈点偆銈 | 鍚告皸鍙f帴缍氬彛銇偟銈ゃ偤銆
娉ㄦ剰锛氬悓銈点偆銈恒伄鍚告皸鍙f帴缍氬彛銇屻仾銇勩倐銇仺銇椼伨銇欍 |
|
CoverLength |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Cover Length | The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the gully trap. |
| 銈儛銉笺伄闀枫仌 | 灞鎵搴ф绯汇伄X杌搞伀娌裤亞銇嬨佸崐寰勶紙鍐嗙姸銇舰銇牬鍚堬級銇ф脯瀹氥仌銈屻仧婧濋槻鑷紒銈儛銉笺伄闀枫仌銆 |
|
CoverWidth |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
| Cover Width | The length measured along the y-axis in the local coordinate system of the cover of the gully trap. |
| 銈儛銉笺伄骞 | 灞鎵搴ф绯汇伄Y杌搞仹娓畾銇曘倢銇熸簼闃茶嚟寮併偒銉愩兗銇暦銇曘 |
|