7.6.4.22 Pset_WasteTerminalTypeGullyTrap

PSET_TYPEDRIVENOVERRIDE / IfcWasteTerminal / GULLYTRAP

Natural language names
Waste Terminal Type Gully Trap
Properties

buildingSMART Data Dictionary

PSD-XML

NameTypeDescription
NominalBodyLength P_SINGLEVALUE / IfcPositiveLengthMeasure
Nominal Body LengthNominal or quoted length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the chamber of the gully trap.
鍛肩О韬綋闀婧濋槻鑷紒銇崐寰勩亱灞鎵搴ф绯汇伄锛歌桓銇部銇c仸娓畾銇曘倢銇熷懠绉般倐銇椼亸銇⿳绠椼仌銈屻仧闀枫仌銆
NominalBodyWidth P_SINGLEVALUE / IfcPositiveLengthMeasure
Nominal Body WidthNominal or quoted length measured along the y-axis in the local coordinate system of the chamber of the gully trap.
鍛肩О韬綋骞婧濋槻鑷紒銇崐寰勩亱灞鎵搴ф绯汇伄锛硅桓銇部銇c仸娓畾銇曘倢銇熷懠绉般倐銇椼亸銇⿳绠椼仌銈屻仧闀枫仌銆
NominalBodyDepth P_SINGLEVALUE / IfcPositiveLengthMeasure
Nominal Body DepthNominal or quoted length measured along the z-axis in the local coordinate system of the chamber of the gully trap.
鍛肩О韬綋娣便仌婧濋槻鑷紒銇崐寰勩亱灞鎵搴ф绯汇伄Z杌搞伀娌裤仯銇︽脯瀹氥仌銈屻仧鍛肩О銈傘仐銇忋伅绌嶇畻銇曘倢銇熼暦銇曘
GullyType P_ENUMERATEDVALUE / IfcLabel / PEnum_GullyType
Gully TypeIdentifies the predefined types of gully from which the type required may be set.
闃茶嚟寮併伄绋瑷疆銇欍倠浜堝畾銇簼銈掋亗銈夈亱銇樸倎瀹氱京銇с偪銈ゃ儣銈掔⒑瑾嶃仐銇俱仚銆
HasStrainer P_SINGLEVALUE / IfcBoolean
Has StrainerIndicates whether the gully trap has a strainer (= TRUE) or not (= FALSE).
銈嶉亷瑁呯疆婧濄伄闃茶嚟寮併亴銈嶉亷瑁呯疆銈掑倷銇堛仸銇勩倠銇嬨仼銇嗐亱銇寚绀恒
TrapType P_ENUMERATEDVALUE / IfcLabel / PEnum_TrapType
Trap TypeIdentifies the predefined types of trap from which the type required may be set.
闃茶嚟寮併伄绋銈汇儍銉堛仌銈屻倠浜堝畾銇槻鑷紒銇亗銈夈亱銇樸倎瀹氱京銇曘倢銇熴偪銈ゃ儣銈掔⒑瑾嶃仐銇俱仚銆
OutletConnectionSize P_SINGLEVALUE / IfcPositiveLengthMeasure
Outlet Connection SizeSize of the outlet connection from the object.
鎺掓皸鍙f帴缍氬彛銈点偆銈瑕佺礌銇嬨倝銇帴缍氬彛銈点偆銈恒
BackInletPatternType P_ENUMERATEDVALUE / IfcLabel / PEnum_BackInletPatternType
Back Inlet Pattern TypeIdentifies the pattern of inlet connections to a gully trap. A gulley trap may have 0,1,2,3 or 4 inlet connections and the pattern of their arrangement may vary. The enumeration makes the convention that an outlet is either vertical or is placed at the bottom (south side) of the gully trap (when viewed in plan). Position 1 is to the left (west), position 2 is to the top (north), position 3 is to the right (east) and position 4 is to the bottom (south).
InletConnectionSize P_SINGLEVALUE / IfcPositiveLengthMeasure
Inlet Connection SizeSize of the inlet connection(s), where used, of the inlet connections. Note that all inlet connections are assumed to be the same size.
鍚告皸鍙f帴缍氬彛銈点偆銈鍚告皸鍙f帴缍氬彛銇偟銈ゃ偤銆 娉ㄦ剰锛氬悓銈点偆銈恒伄鍚告皸鎺ョ稓鍙c亴銇亜銈傘伄銇ㄣ仐銇俱仚銆
CoverLength P_SINGLEVALUE / IfcPositiveLengthMeasure
Cover LengthThe length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the gully trap.
銈儛銉笺伄闀枫仌灞鎵搴ф绯汇伄X杌搞伀娌裤亞銇嬨佸崐寰勶紙鍐嗙姸銇舰銇牬鍚堬級銇ф脯瀹氥仌銈屻仧婧濋槻鑷紒銈儛銉笺伄闀枫仌銆
CoverWidth P_SINGLEVALUE / IfcPositiveLengthMeasure
Cover WidthThe length measured along the y-axis in the local coordinate system of the cover of the gully trap.
銈儛銉笺伄骞灞鎵搴ф绯汇伄Y杌搞仹娓畾銇曘倢銇熸簼闃茶嚟寮併偒銉愩兗銇暦銇曘

Link to this page  Link to this page